Flashing Unit: 1 or 2 Flashes / Second or Constant Burn
• 1.5ft Line Cord w/ IEC-320 (C14) Line Receptacle
• (OPTIONAL)...Pull-Chain on/off Switch
• Line Load Regulated (30mA self adjusting Output
regardless of load size or Input voltage fluctuations.)
• High Power Factor (Energy Saving/Cost Effective)
• Ground Connection via Mounting Foot
• UL2161 listed
• Complies with CSA22.2, No. 107.1, No. 13
• Open Circuit & Overload Will Shut Unit Down.
NOTE:
Under a fault condition, unit will attempt to reset 2 more times, then latch off permanently unless the fault clears. Intermittant faults will not effect the operation of the unit.
SPECIFICATIONS
Input Voltage 120 VAC (±10%) 50/60Hz
Input Current 0.9 A (Max)
Power Factor High (.93)
Output Frequency Variable
Output Voltage 100V - 9000V
Output Current 30mA
Operating Temperature 32° to 104°F (0° to 40°C)
Driving Distance (Based on Standard 12mm tube. Deduct one foot from driving
footages for each additional pair of electrodes)
Neon 4-26 ft, (1.2-7.9 m)
Mercury 4-31 ft, (1.2-9.4 m)